          | MATS-2010H                 
 Soft Magnetic Material Dynamic Hyteresisgraph System  page print  
        
        
          | 
              
              
                | Model MATS-2010H |  |  |  
                |  |  
              
              
                | 
 | 
                    
                    
                      | Automatic 
                        measurement on hysteresis loop and demagnetization curve 
                        of permanent-magnet material, accurate measurement on 
                        magnetic characteristic parameters such as remanence Br, 
                        coercive force HcB, intrinsic coercive force HcJ and 
                        maximum magnetic energy product (BH)max. 
 Windows 
                        measurement software applied simply. The product 
                        conforms to China National Standards GB / T3217 - 92 and 
                        international standard IEC404 - 
                        5.
 
 Adopt ATS structure, users can 
                        customize different configuration as 
                        required:  According to the size of measured 
                        sample to determine electromagnet size and correspondent 
                        test source power; Select different measuring coil and 
                        probe according to testing method; Determine whether 
                        selecting jig according to sample shape; Determine 
                        whether selecting heating system according to test 
                        requirement.
 |  |  
 
              
              
                | System Specifications Test Alnico standard sample, measuring error on entire 
                  magnetic hysteresis cycle estimated: B: 1_ H: 1_  
                    
                      | Parameters measured | Br(%) | HcB(%) | HcJ 
(%) | (BH)max(%) |  
                      | Uncertainty (k=2) | 1 | 1 | 1 | 2 |  
                      | Repeatability (constant temperature) | ± 0.3 | ± 0.3 | ± 0.3 | ± 1 |  Instrument Specifications 
                    
                    
                      | TPS-2000H Test Power Supply |  | DCT150 Electromagnet |  
                      | Output Voltage: 0 
                        ~±100V Output Current:±20A 
                        (maximum value)
 Stability: 
                        superior to 0.05%
 Stability: 
                        superior to 0.05%
 | Head Diameter: 150mm 
                        shrink to 80mm Head Spacing: 
                        0 ~ 50mm (continual 
                        adjustable)
 Maximal Magnetic 
                        Field: 2.4T (head spacing 10mm, coil current 30A)
 |  
                      | LZ-210B Fluxmeter | DCT200 Electromagnet |  
                      | Range: 2.5, 5, 10, 20 
                        mWb Full Range Precision: 
                        0.5%
 Zero Shift: 2μWb /30 
                        seconds (2.5mWb)
 | Head Diameter: 200mm 
                        shrink to 120mm Head Spacing: 
                        0 ~ 50mm (continual 
                        adjustable)
 Maximal Magnetic 
                        Field: 2.4T (head spacing 10mm, coil current 40A)
 |  
                      | LZ-210H Magnetometer | DCT250 Electromagnet |  
                      | Range: 0.5, 1, 1.5, 3 
                        T Full Range Precision: 0.5%
 Non-Linearity:±0.2% 
                        (software correction)
 | Head Diameter: 250mm 
                        shrink to 150mm Head Spacing: 
                        0 ~ 50mm (continual 
                        adjustable)
 Maximal Magnetic 
                        Field: 2.7T (head spacing 10mm, coil current 80A)
 |  
                      | DCT130 Electromagnet | PC6011 A/D D/A card |  
                      | Head Diameter: 
                        130mm Head Spacing: 0 ~ 50mm 
                        (continual 
                        adjustable)
 Maximal Magnetic 
                        Field: 1.5T (head spacing 10mm, coil current 20A)
 | A/D Conversion: 
                        12Bit, 32 channels Conversion Time: < 10μs
 Conversion Accuracy: 0.05% 
                        (full range)
 D/A Conversion: 
                        12Bit, 2 channels
 Setup 
                        Time: < 10μs
 |  
 |  
                |  |    
  
                | 
                       
                        | 
                     
                      | 
                          
                             
                              |  Series of machinery for magnetic industry for your choice  |   
                              |  |  |   
                      |  |  
                            Download :
                            Download Catalog(zip file 
                            for .doc)of magnetizer: DOWNLOAD 
                            NOW! |  |  |  
  
    |  ©Copy Right 2001 YUXIANG All Rights 
        Reserved Add :F/16, Jinyuan plaza, # 57 South Hubin.Rd, Xiamen, CHINA
 361004
 Tel : (86)592 2295387 (86)592 2217138 Fax: (86)592 2207122